![]() ![]() POWERLINE COUPLING / DECOUPLING NETWORKS FOR EN 61000-4-6 CDN-M125E (model) Single line, 25 Amp, 150 kHz -230 MHz (description) CDN-M225E Single line + Netural, 25 Amp, 150 kHz - 230 MHz CDN-M325E Single line + Netural + Earth, 25 Amp, 150 kHz - 230 MHz CDN-M425 Three phase + Netural, 25 Amp, 150 kHz - 80 MHz CDN-M525 Three phase + Netural+ Earth, 25 Amp, 150 kHz - 80 MHz CDN-C50E 50 Ohm coax cable, 150 kHz - 230 MHz CDN-C75 75 Ohm coax cable, 150 kHz - 80 MHz CDN-S1 Shielded cable with 1 conductor,150 kHz - 80 MHz CDN-S2 Shielded cable with 2 conductors,150 kHz - 80 MHz CDN-S4 Shielded cable with 4 conductors,150 kHz - 80 MHz CDN-S9 Shielded cable with 9 conductors,150 kHz - 80 MHz CDN-S15 Shielded cable with 15 conductors,150 kHz - 80 MHz CDN-S25 Shielded cable with 25 conductors,150 kHz - 80 MHz CDN-S36 Shielded cable with 36 conductors,150 kHz - 80 MHz CDN-AF2E Unshielded cable with 2 conductors,150 kHz - 230 MHz CDN-AF4E Unshielded cable with 4 conductors,150 kHz - 230 MHz CDN-AF8 Unshielded cable with 8 conductors,150 kHz - 80 MHz CDN-T2E Unshielded cable with 2 balanced conductor pairs,150 kHz - 230 MHz CDN-T4E Unshielded cable with 4 balanced conductor pair s, 150 kHz - 230 MHz CDN-T8 Unshielded cable with 8 balanced conductor pairs,150 kHz - 80 MHz CDN-T8SE Four balanced pair - screened, 150 kHz - 230 MHz CDN CALIBRATION ACCESSORIES ADA-515-2 (model) 150 Ohm to 50 Ohm adapter (description) TEP-050 50 Ohm terminator ADA-M1 shorting adapter for CDN-M125 ADA-M2 shorting adapter for CDN-M225 ADA-M3 shorting adapter for CDN-M325 ADA-M4 shorting adapter for CDN-M425 ADA-M5 shorting adapter for CDN-M525 ADA-C50 shorting adapter for CDN-C50 ADA-C75 shorting adapter for CDN-C75 ADA-S1 shorting adapter for CDN-S1 ADA-S2 shorting adapter for CDN-S2 ADA-S4 shorting adapter for CDN-S4 ADA-S9 shorting adapter for CDN-S9 ADA-S15 shorting adapter for CDN-S15 ADA-S25 shorting adapter for CDN-S25 ADA-S36 shorting adapter for CDN-S36 ADA-AF2 shorting adapter for CDN-AF2 ADA-AF4 shorting adapter for CDN-AF4 ADA-AF8 shorting adapter for CDN-AF8 ADA-T2 shorting adapter for CDN-T2 ADA-T4 shorting adapter for CDN-T4 ADA-T8 shorting adapter for CDN-T8 Coupling Decoupling Network (CDN) for Conducted Immunity testing For Conducted Immunity Testing Meets EN-61000-4-6 Requirements Powerline Testing Signal line Testing Three Year Warranty Coupling Decoupling Networks (CDNs) for IEC / EN 61000-4-6 Testing Com-Power CDNs are designed and constructed to comply with standard EN 61000-4-6 Immunity to Conducted Disturbances Induced by Radio Frequency Fields (also IEC-1000-4-6 and CISPR 16). Electronic products can be susceptible to interference from nearby transmitters due to signal coupling to external I/O cables of the product's This is especially true for products with long external power, communication and interface cables. The level of interference that product must be able withstand is defined in the standard. A CDN is used to couple the disturbing signals to the product I/O cables. These levels are are injected into the CDN using a suitable power amplifier (similar to Com-Power ACS-181 or ACS-230) and an RF signal generator. The CDN consists of circuits for coupling and decoupling injected RF signals. The the coupling circuit injects the disturbing signal into the cables under test.. The decoupling circuit prevents the injected signal from reaching the auxiliary equipment (AE) connected to the EUT. Each CDN is specific to the type of cable and corresponding connector. Com-Power offers an extensive range of CDNs to test most standard cable types. You may require additional CDNs to decouple or isolate all other cables that are not subjected to the test, but are connected to the EUT. EN 61000-4-6 standard requires that an appropriate CDN be connected in this situation. Each CDN is calibrated to meet the performance requirement given in IEC-61000-4-6 standard prior to shipment. The impedance data and certificate of calibration is shipped with each unit. Below is a brief description of each CDN type available from Com-Power: M series CDNs for power line cables Coupling Decoupling Networks are recommenced for all power supplies connections. The disturbing signals are to coupled to each conductor in the supply lines according to EN 61000-4-6 standard. The standard M series CDNs have a current rating of 25 Amps. Com-Power CDNs are available for power supplies from 1 to 5 conductors. These CDNs cover the frequency range of 150 kHz - 230 MHz. C series CDNs for shielded coax cables The C series CDNs are for coupling disturbing signals on to 50 Ohm (CDN-C50) and 75 Ohm (CDN-C75) shielded coax cables. These CDN have BNC connectors for EUT and AE connections. AF series CDNs for unshielded signal cables The AF series CDNs are for unshielded cables with two, four and eight conductors carrying low current. AF series CDNs are supplied with RCA connectors. S Series CDNs for shielded signal cables The S series CDNs are for shielded cables with single or multiple conductors. These CDNs are supplied with professional audio (RCA), D type and Centronics connectors. T series CDNs for unshielded balanced pairs The T series CDNs are for cables with unshielded balanced conductor pairs typically found in ISDN, DSL and Ethernet data transfer applications. Calibration accessories for The CDN The RF disturbance levels that EUT has to be subjected to (1 V/m, 3 V/m, 10 V/m RMS) is specified in EN-61000-4-6. The conducted immunity setup must be calibrated make sure the proper levels are being generated during the compliance test. This setup includes signal generator, power amplifier, directional coupler, CDN, attenuator, cables, etc. In order determine disturbance levels being generated the following additional accessories are needed. These adapters are made according to the requirements specified in EN-61000-4-6. One set of shorting adapters for each type of CDN - Part# ADA-xxx ( xxx = model number) Two 150 Ohm to 50 Ohm adapter - ADA-515 50 Ohm terminator - Part # - TEP -050 |
![]() |